- Manuals
- Brands
- Industrial Electrical
- IntelliRupter PulseCloser
- Installation manual
Fault interrupter
Hide thumbs Also See for IntelliRupter PulseCloser:
- Manual (181 pages) ,
- Installation manual (23 pages) ,
- Instruction sheet (16 pages)
-
- Contents
- Table of Contents
- Bookmarks
Table of Contents
-
Table of Contents
- Table of Contents
- Introduction
-
Qualified Persons
-
Read this Instruction Sheet
-
Retain this Instruction Sheet
-
Proper Application
-
Special Warranty Provisions
-
- Safety Information
-
Understanding Safety-Alert Messages
-
Following Safety Instructions
-
Replacement Instructions and Labels
-
Location of Safety Labels
-
- Safety Precautions
- Appendix A
- Inspection
-
Control Power
-
- Installation
-
Installing the External Interface Assembly
-
Wiring
-
- Application Notes
-
Inputs
-
Intelliteam ® SG Automatic Restoration System
-
Latched Inputs
-
Outputs
-
Advertisem*nt
Quick Links
Download this manual
IntelliRupter
PulseCloser
®
Outdoor Distribution (15.5 kV, 27 kV, and 38 kV)
Table of Contents
Section
Introduction
Qualified Persons . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Read this Instruction Sheet . . . . . . . . . . . . . . . . . . . 2
Retain this Instruction Sheet . . . . . . . . . . . . . . . . . . . 2
Proper Application . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Special Warranty Provisions . . . . . . . . . . . . . . . . . . . 3
Safety Information
Understanding Safety-Alert Messages . . . . . . . . . . . 4
Following Safety Instructions . . . . . . . . . . . . . . . . . . 4
Replacement Instructions and Labels . . . . . . . . . . . 4
Location of Safety Labels . . . . . . . . . . . . . . . . . . . . 5
Safety Precautions
. . . . . . . . . . . . . . . . . . . . . . . . . 6
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
May 4, 2020
© S&C Electric Company 2018-2020, all rights reserved
Fault Interrupter
®
External Interface Installation
Page
Section
Inspection
Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Control Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installation
Installing the External Interface Assembly . . . . . . . . 9
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Application Notes
Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
IntelliTeam
®
SG Automatic Restoration System . . . .13
Latched Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Appendix A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Instruction Sheet 766-514
Page
Advertisem*nt
Table of Contents
Related Manuals for S&C IntelliRupter PulseCloser
-
Fault interrupter (181 pages)
-
Fault interrupter outdoor distribution (23 pages)
-
Fault interrupter wi-fi, scada, and gps communication setup (16 pages)
-
Compact fault interrupter (2 pages)
-
Outdoor distribution (31 pages)
-
Underground distribution switchgear. outdoor distribution with visi-gap load-interrupter switches and visi-gap fault interrupters (27 pages)
-
Pad-mounted gear, outdoor distribution (32 pages)
-
Cutout-mounted recloser outdoor distribution (36 pages)
-
Circuit-switchers-mark vi outdoor transmission (56 pages)
-
Switching system (20 pages)
-
Underground distribution switchgear (27 pages)
-
Cutout-mounted recloser (132 pages)
-
Dropout recloser (24 pages)
-
Cutout-mounted recloser (89 pages)
-
Cutout-mounted recloser (15 pages)
Summary of Contents for S&C IntelliRupter PulseCloser
-
Page 1: Table Of Contents
IntelliRupter PulseCloser Fault Interrupter ® ® Outdoor Distribution (15.5 kV, 27 kV, and 38 kV) External Interface Installation Table of Contents Section Page Section Page Introduction Inspection Qualified Persons . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Inspection . -
Page 2: Introduction
Thoroughly and carefully read this instruction sheet and all materials included in the product’s instruction handbook before installing or operating an IntelliRupter PulseCloser Fault Interrupter . Familiarize yourself with the Safety Information and Safety Precautions on pages 4 through 6 . -
Page 3: Special Warranty Provisions
Introduction Special Warranty The standard warranty contained in S&C’s standard conditions of sale, as set forth in Price Sheets 150 and 181, applies to the IntelliRupter fault interrupter, except that the Provisions first paragraph of the said warranty is replaced by the following: (1) General: The seller warrants to the immediate purchaser or end user for a period of 10 years from the date of shipment that the equipment delivered will be of the kind and quality specified in the contract description and will be free of defects of... -
Page 4: Safety Information
Safety Information Understanding Several types of safety-alert messages may appear throughout this instruction sheet and on labels attached to the IntelliRupter PulseCloser Fault Interrupter. Familiarize Safety-Alert Messages yourself with these types of messages and the importance of these various signal words: DANGER “DANGER”... -
Page 5: Location Of Safety Labels
Safety Information Location of Safety Labels WARNING WARNING ELECTROCUTION HAZARD IntelliRupter fault interrupter base contains electrical ® Failure to follow these instructions can cause serious injury or death. and mechanical parts that can cause injury. • This IntelliRupter ® PulseCloser ®... -
Page 6: Safety Precautions
Safety Precautions DANGER IntelliRupter PulseCloser Fault Interrupters operate at high voltage. Failure to observe the precautions below will result in serious personal injury or death. Some of these precautions may differ from your company’s operating procedures and rules . Where a discrepancy exists, follow your company’s operating procedures and rules . -
Page 7: Overview
Overview An IntelliRupter fault interrupter with catalog number suffix “-C11” is shipped with the SDA-5799 Protection and Control Module shown in Figure 1. This control features a fiber-optic interface that allows the control to be connected to an external interface assembly. There are two versions of external interface assembly. -
Page 8: Inspection
Inspection Inspection Examine the shipment for external evidence of damage as soon after receipt as possible. If there is visible loss and/or damage: 1. Notify the delivering carrier immediately. 2. Ask for a carrier inspection. 3. Note condition of shipment on all copies of the delivery receipt. -
Page 9: Installation
Installation Installing the External Interface Assembly STEP 4. Determine conduit access needs and remove the gland plate. Add the connection holes as Follow these steps to install the external interface needed. See Figure 6 for location of the gland assembly: plate. - Page 10 Installation STEP 7. Install the conduit for the customer supplied NOTICE connections and the external power supply conduit to the external interface assembly. See The minimum bend radius for the fiber optic cable is Figure 7. 4 .25 inches (108 mm) . STEP 8.
-
Page 11: Wiring
Installation Wiring Follow these steps to install wiring to the terminal blocks: STEP 1. Terminal blocks for control power require wires terminated with ring or spade lugs suitable for use with #10 screws. Refer to the “Control Power” section on page 8 and attach the external interface assembly power connections to terminal strip TB 1. - Page 12 Installation connection from J19 (1-10) /P3 and transfer it to STEP 4. The output relays provide a form C contact the same location on J19 (11-20) /P4. See configuration as shown in Figure 9. The common Figure 8 on page 11 for the detailed terminal contact of each output relay is connected to the designations.
-
Page 13: Application Notes
Application Notes Inputs There are defined Function Inputs where functions correspond to the input name and Spare Inputs that will be assigned functions through IntelliLink® Setup Software. See S&C Instruction Sheet 766-530 for the available settings. Table 3. Defined Function Inputs Input Name Description Terminal... -
Page 14: Outputs
Application Notes Outputs There are defined Function Outputs where functions correspond to the output name and Spare Outputs that will be assigned functions through the IntelliLink Setup Software. See S&C Instruction Sheet 766-530 for the available settings. Each output has a normally open contact and a normally closed contact. - Page 15 Appendix A Dimensions in inches (mm) Figure 11. Mounting bracket dimensions. S&C Instruction Sheet 766-514 15...